Knowledgebase

Flex System 1 audit trail events

  • 0

..//assets/img/kb/date.png Flex 1 System Audit Trail Events

Audit trail events below are for the original Flex System. Events for the Flex II system are here.

  Message Description Data
1 System Reset A command was sent from CyberAudit-Web to reset the hub. The resulting behavior is the same as a power cycle. N/A
2 Firmware Updated CyberAudit-Web sent new firmware. This event is recorded following the restart after loading the new firmware. N/A
3 Reset to Factory Settings The hub received a reformat command which reverts the hub to factory settings. Includes clearing network settings. This command is not included in CyberAudit-Web. N/A
4 All Data Cleared The hub received and executed a command to delete all stored permissions. N/A
5 UTC offset updated UTC offset read from configuration file UTC offset in minutes
6 Clock Stopped Clock registers indicate the time is no longer reliable N/A
7 No transformer power detected   Power status info
8 Transformer power detected   Power status info
9 Battery power detected   Power status info
10 Battery power not detected   Power status info
11 Critical battery detected Battery voltage is below 10V on a 12V system or below 20V on a 24V system Power status info
12 Low battery detected Battery voltage is below 12V on a 12V system or below 24V on a 24V system Power status info
13 USB flash drive detected A readable USB flash drive was inserted N/A
14 USB flash drive removed   N/A
15 Data written to USB   Drive ID, File ID, list of tasks performed: Fetched current configuration data Fetched hub audit trail Fetched CyberKey audit trails Updated network settings Cleared hub audit trails Cleared key audit trails
16 Internal memory error The hub encountered an error reading or writing it memory. The data is the raw hexascii diagnostic bytes
17 No network connection The hub did not detect a network  
18 Network connection restored A network was detected  
19 Failed to contact CyberAudit-Web Connection to CyberAudit-Web was lost. If present, the Green OK icon will be cleared in the Flex System Hubs listing page.  
20 Connection established to CyberAudit-Web Connection to CyberAudit-Web succeeded. The Green OK icon will now show in the Flex System Hubs listing page.
21 Connection to proxy failed   TCP/IP status code
22 Connection established to proxy    
32 Valid CyberKey inserted into Vault   CyberKey serial number
33 Invalid CyberKey inserted into Vault The hub did not find the CyberKey serial number in its list of valid keys for the Vault.  
34 CyberKey removed    
35 RFID scan   ID of the card
36 Data received from I/O module   Data received
37 Keypad input received Mission, issue, or PIN Input device, number of characters entered
38 People record verified   Name of person
39 CyberKey configuration verified   The name of the mission or key
40 Access Granted - Door lock released   Name of door
Name of person
41 Found issued key record The Flex hub found the record of the person who owns the key Key ID
42 Access granted to Vault   Name of Vault
43 PIN verified The PIN entered matched the PIN on record for the person. Input device, number of characters entered
44 Request to exit Received RTE input signal Name of door
45 Door closed Door sensor returned to closed position Name of door
46 Door opened Door sensor changed to open position Name of door
47 IHS button input received Input received to generate inter-hub signal Name of door
48 IHS received Inter-hub signal received via network Sender:
Receiver:
Time:
Level:
Mode:
Type:
Class:
Group:
Port:
Input type:
Controls:
49 IHS response completed IHS response duration was served. The response has ended. Type of module:
Name of associated door:
50 Begin "keep unlocked" schedule   Name of door
52 Door schedule completed   Name of door
53 Door opened without access permissions A door sensor indicates the door changed to the open position without any associated permissions. Name of door
54 RTE denied Request to exit was received when an inter-hub signal response or other condition had higher priority Name of door
55 IHS input rejected Inter-hub signal input received while still responding to a previous inter-hub input Name of door
57 Door left open too long A door was left open past its alarm timer Name of door
58 Door release timed out The solenoid, mag lock, or other mechanism that released the door to open reached the end of its "hold open" time but the hub did not receive a response from the Door and I/O Module. As a result, the hub has cancelled the command to the module to open the door. Name of person
Name of door
59 Deadbolt line open The optional Deadbolt input toggled open ID of Door and I/O module
60 Deadbolt line closed The optional Deadbolt input toggled closed ID of Door and I/O module
61 Generic button pressed Optional Generic Button input pressed ID of Door and I/O module
62 Generic switch toggled Optional Generic Switch closed ID of Door and I/O module
65 Key comm failed Communications with the CyberKey failed. Ensure all contacts are clean. CyberKey serial number ID
67 Key downloaded The audit trail was captured from a CyberKey. Key serial number ID
68 Key configured The Flex hub gave the CyberKey an updated configuration Name of person
Key serial number ID
Configuration ID
69 Key disabled The ability to open CyberLocks was removed from the CyberKey Key serial number ID
74 Door lock re-activated The Door and I/O module re-activated the door lock.  
75 Issued key inserted into keyport The key ID was issued to a person and the record was found in the hub database. Key ID
76 Unknown key inserted into keyPort The key ID is not in the list of vault keys or keys known to the system. The Flex hub attempts to notify CyberAudit-Web. Key ID
77 Missionable key inserted into keyPort The key ID was found in the Flex hub's list of keys known to the system. The Flex hub prompts for an ISSUE # or MISSION #. Key ID
78 Key downloaded from server The key was downloaded in response to a request from CyberAudit-Web. Key ID
79 Key programmed from server The key was programmed from a configuration sent by CyberAudit-Web. Key ID
82 Out of schedule for Weatherized Vault(s) The person attempted to check out a CyberKey from a Weatherized Vault during a time outside of their scheduled time frames for the vaults on the Flex System Hub. Name of person
83 Mission expired The person attempted to check out a mission from a Weatherized Vault after the mission had expired. Name of person
Name of mission
86 RFID not found The hub did not find the ID of the RFID card in its list of people or missions. ID of the card
87 Mission number not found The hub did not find a mission number matching the one entered at the keypad. Mission number entered
88 No stored CyberKey configuration found A mission number was found but no corresponding CyberKey programming instructions were found. Mission template name
89 No door permissions found The person was found but there were no associated permissions for the door. Name of door
92 No door record found The person was found but there was no information found for the door.  
96 PIN input module not available Access to a Vault or door requires entry of a PIN but no Data Knob, Keypad, or other device is available in the group.  
98 Vault opened The Weatherized Vault was opened. Name of Person
Name of Vault
99 Vault latched The Weatherized Vault lid was returned to the closed position that captures it in its latch. Name of Person
Name of Vault
100 Access out of schedule A person attemted access to a door outside of their scheduled time frames for the door Name of person
Name of door
102 Access attempted during IHS lockdown   Name of person
Name of door
IHS details
105 Input received to cancel hold-open or first person in CyberAudit-Web Enterprise sends this signal to the Flex System hub in these cases: A Suspend Hold Open is sent from CyberAudit-Web CyberAudit-Web sends updated information to the Flex Hub where the Door group will be affected. Name of door
107 Special action request received An Input # or RFID card scan generated an Open Vault request. Or a Request to open request was sent to open a Door. Request detail: Request to open Vault Request to open Door Request to open Vault 20 FX and unlock socket Request to remove invalid key from a Vault 20 FX Request to open Vault to return key
108 Requested mission already checked out Flex System hubs will track missions checked out and will not issue a second CyberKey for the same mission. CyberAudit-Web also updates all Flex hubs in the system when a mission is checked out from a Vault on another hub. Name of mission
Name of person
109 Mission # not found The Flex hub did not find the mission number entered in its list of cached missions. Mission # entered
111 Key Ring inserted A Key Ring CyberKey has been identified Key ID
112 Module firmware update failed    
113 Module firmware update successful    
114 Hub data cleared The hub received a command to clear one or more of its stored records or data. A list of the data types cleared
115 Special keypad input Three or fewer digits were entered and submitted from a keypad/display. Input received
116 New PIN input received The key holder successfully entered and confirmed a new PIN.  
117 CyberKey firmware updated    
118 Hardware reset A hardware reset was performed on the Flex System hub.  
119 Keypad input requested from server CyberAudit-Web requested user input Keypad input
(Three characters or less)
120 Requested RFID input sent to server CyberAudit-Web requested RFID scan input ID of the card
121 Card scan - mission option presented RFID input was received for a system where multiple missions per card are available to select  
122 Mission selected The mission Mission name or number
128 System restart to free up operating memory (heap space 1) The system has used up available heap 1 memory. System is restarting to free up operating memory.  
129 System restart to free up operating memory (heap space 2) The system has used up available heap 2 memory. System is restarting to free up operating memory.  
130 System Error Error details shown in the data column Error category and detail
131 Firmware execution error (131) Contact Flex System reseller  
28161 External power detected The Vault 20 FX powerboard detected primary power source is now its external (transformer)  
28163 POE power detected The Vault 20 FX powerboard detected primary power source is now Power Over Ethernet  
28165 Battery power detected The Vault 20 FX powerboard detected primary power source is now from battery  
28176 Door release button released The door release button is located inside the front panel of the Vault 20 FX  
28177 Door release button pressed    
28192 FX Door opened The door on the Vault 20 FX was opened  
28193 FX Door closed The door on the Vault 20 FX was closed  
28210 Low battery detected The Vault 20 FX detected low voltage on its battery. Its charge is less than 50% capacity.  
28211 Critical battery detected Vault 20 battery life is at approximately 2 minutes

CyberKey and CyberLock audit trail events
WebStation 2 audit trail events
Portable Link audit trail events
Web Authorizer audit trail events
LAN Authorizer audit trail events