Knowledgebase

Flex 1 System Display Messages

  • 0

Flex 1 System Display Messages

The following is a list and discription of messages which may appear on a display connected to the original model Flex System hub. Messages for the Flex II system are here.

User interactions
System messages and errors

Messages at setup and administration


Message Description
Messages at Setup and Administration
UNKNOWN
USB
DEVICE
A USB device was not recognized as a mass storage type by the Flex System hub. The drive must be formatted as FAT or FAT32.
LOAD NET
SETTINGS
The Flex System hub is loading network settings from a USB configuration. This message normally will not be seen because the process happens very quickly.
BAD NET
SETTINGS
The USB network configuration settings failed an integrity check.
BAD
PROXY
SETTINGS
The proxy settings received from USB failed an integrity check.
BAD
CONFIG
The USB configuration file failed an integrity check.
DOWNLOAD
STATUS
Indicates the Flex System hub is writing its status and diagnostic information to a USB flash drive.
DOWNLOAD
FLEX
EVENTS

DOWNLOAD
KEY
EVENTS
Indicates the Flex System hub is writing its audit trail events to a USB flash drive based on instructions received in the fetch diagnostics page.
USB
READY
The Flex System hub successfully wrote the requested data to the USB flash drive. The drive may now be removed.
CHECK
USB
FORMAT
The Flex System hub discovered a newly inserted USB flash drive and is determining whether it can decipher the format of the drive.
BAD
USB
FORMAT
The Flex System hub could not decipher the format of the newly inserted USB flash drive.

User Interactions


Message Description
User Interaction
PIN" The person record was found and requires a PIN be entered to validate identity.
BAD PIN The PIN entered does not match the PIN on record for the identified person.
ENTER
NEW PIN
The user has been identified by RFID card scan or mission number and must create a new PIN. At this point 4 to 8 digits must be entered followed by the ,#,.
CONFIRM
NEW PIN
The user has just entered a new PIN and must enter the new PIN again to confirm it is correct.
READY The Flex System hub is idle but it does not have a connection with CyberAudit-Web.
READY* The Flex System hub is idle and has a connection to CyberAudit-Web.
BUSY The Flex System hub is processing a command or request.
UNKNOWN
CARD
The scanned RFID access card was not recognized.
LINKUP
HOST
The Flex System hub did not recognize the scanned RFID card, entered mission #, or inserted CyberKey and is attempting to contact CyberAudit-Web for resolution.
UNKNOWN
MISSION
The mission entered using the Data Knob or Keypad Display was not recognized.
ACCESS
EXPIRED
The schedule paired with the Door or Vault(s) has expired for the person attempting access or the mission is past its Final End Date.
ACCESS
OUT OF
SCHEDULE
Access was attempted to the Door or Vault(s) outside the time frames of the scheduled access for the person.
NO
ACCESS
The person assigned to the RFID access card or mission # does not have permission to access the door or to use the Vault.
RETURN
KEY
Instuction to return a CyberKey to a Vault from a mission.
KEY IN
CLOSE
VAULT
Once the Flex System hub determines that the key inserted into the Weatherized Vault is valid it displays this message.
INVALID
KEY
An invalid key was inserted into a Weatherized Vault or Vault 20 FX. CyberAudit-Web evaluates the key ID. If that ID is eligible to assign to the Flex Hub, it will do so automatically and update the hub at the next opportunity.
REMOVE
INVALID
KEY
A CyberKey in the current Vault is not valid. If it is in a Weatherized Vault, it must be removed from the Vault to resume normal operations.
KEY IN A CyberKey was inserted into a Vault 20 FX or Keyport.
DISABLE
KEY
CyberAudit-Web sent a configuration to the CyberKey to disable all access priviledges.
KEY OUT
CLOSE
VAULT
A CyberKey was removed from a Weatherized Vault.
KEY OUT A CyberKey was removed from a Vault 20 FX or a Keyport.
NO KEY
SETTING
A mission number was found but no corresponding CyberKey programming instructions were found.
MISSION
ALREADY
OUT
The requested mission has already been checked out from another communicator and may not be checked out again until that mission has been checked in.
NO
MISSION
ASSIGNED
No mission is assigned to the scanned RFID access card.
PROGRAM
KEY
Displays when the Flex System hub is loading a CyberKey with a mission or disabling it after returning it to a Vault.
DOWNLOAD
KEY
Displays when the Flex System hub is downloading the audit trail records from a CyberKey.
ISSUE"
or
MISSION"
The CyberKey inserted into the KeyPort may be issued to a person or used with a mission. The user may enter the unique number followed by '"'.
UNKNOWN
ISSUE"
MISSION"
The number entered was not recognized by CyberAudit-Web as either a valid Issue number or Mission.
KEY COMM
FAIL
Indicates the Flex Hub was not able to maintain good communications with a CyberKey. Typically this occurs because of contamination on the key contacts on the Vault and/or the key tips. (CyberKey Cleaning Instructions)
KEY
READY
The CyberKey in the Vault or Keyport is programmed and may be removed.
KEY
ADDITION
DENIED
CyberAudit-Web cannot issue or use the CyberKey for the requested purpose.
KEY
ASSIGNED
TO VAULT
A CyberKey assigned to a Vault was inserted in a Keyport.
UNKNOWN
KEY
A key inserted into a Keyport is unknown to the current system and its flag is set indicating it belongs to another system.
JOB"
OR
ADMIN"
A CyberLock Programmer or Grand Master was inserted into a Keyport and CyberAudit-Web is prompting to enter the programming job number or the admin number of the administrator adding or programming CyberLocks.
BAD JOB"
OR
LOGIN"
CyberAudit-Web did not find a Programming Job or Administrator number matching the number entered.
NEW
KEY

INPUT
ISSUE"
A Grand Master is not a member of the system and must first be issued before configuring it with a programming job.
UNKNOWN
ISSUE"
CyberAudit-Web did not find the Issue Number entered.
ISSUING
KEY
The entered Issue Number was found and CyberAudit-Web is proceeding to add the Grand Master to the system. It will next prompt for a JOB" or LOGIN".
NEW LOCK
LOGIN"
The Grand Master automatically programmed CyberLocks unknown to the system. A LOGIN" is needed to add the locks to the system with visibility at the correct administrator node.
BAD
LOGIN"
CyberAudit-Web did not find the Login Number entered.
NEW LOCK
ADD
DENIED
CyberAudit-Web did not permit adding lock IDs to the system. Check the permissions of the administrator associated with the LOGIN".
OPEN
<name of Vault>
Alternates with the KEY READY message. Instructs to open the Vault to retrieve the programmed CyberKey.
VAULT
OPEN
The door on the Weatherized Vault has been turned away from the locked position.
VAULT
CLOSED
The door on the Weatherized Vault has been returned to the closed and locked position.
NO EMPTY
VAULT
There is no empty Weatherized Vault or key retainer available for returning a CyberKey from a mission.
OPEN
DOOR
Access has been granted to the Door. It may now be opened.
DOOR
OPEN
The Door has been opened. (Requires a door sensor connected to the Door and I/O module.
DOOR
CLOSED
The Door has returned to the closed position. (Requires a door sensor connected to the Door and I/O module.
LINKUP
HOST
The Flex System hub does not have a record cached for the requested access so it is attempting to notify CyberAudit-Web of the request.
KEY
DISABLED
A deleted CyberKey has been cleared of all access permissions. It may now be issued to another person or used with a mission.
NO
KEY

RETURN
KEY
There are no available CyberKeys in the Vault or Vaults but the Vault is open to return a CyberKey if desired.
NO VAULT
OR DOOR
An operation requires a Vault or a Door but there is currently no Vault in the group.
KEY
ADDITION
DENIED
The key in the KeyPort cannot be used because the Key is the wrong type or the mission is no longer valid.

System Messages and Errors


Message Description
System Messages and Errors
NO
VAULT
The group is configured to use a Vault but no physical connection to a Vault is found.
NO VALID
KEY
The person has permission to check a CyberKey out from a Vault but the Vault does not have a valid CyberKey available to issue.
NO DOOR
The Flex System Hub has attempted to operate a Door but could not connect to the associated Door and I/O module.
NOT
VAULT
20 FX
A special key input was entered applicable only to a Vault 20 FX.
IHS DOOR
CLOSE
The Flex Hub received a signal to lock the Door.
IHS DOOR
OPEN
The Flex Hub received a signal to unlock the Door
START
IHS
The hub is responding to an Inter-hub signal.
CANCEL
IHS
The hub received a command to stop responding to an Inter-hub signal.
BAD KEY
SETTING
Occurs if a cached record in the Flex System hub for a mission is corrupt.
RTC STOP The Flex System hub clock stopped. No access will be granted to either a Vault or a Door.
MEMORY
FULL
The Flex System hub memory is full. No additional activity is allowed until it can connect and upload to CyberAudit-Web.
BOOTLOAD
FLEX HUB
The Flex System hub is updating its firmware from CyberAudit-Web.
BOOTLOAD
MODULE
The Flex System hub is updating the firmware of one of its modules.
BOOTLOAD
FAIL
A firmware update process failed.
BYPASS
MODE
The Flex System hub needs to contact CyberAudit-Web about an unknown key in its Keyport but the permission to contact has been disabled.
DEADBOLT
UNLOCK
An input configured as a Deadbolt is reporting open.
DEADBOLT
LOCK
An input configured as a Deadbolt is reporting closed.

Was this answer helpful?